TRANSPORTATION T80206 1993: FUEL SYSTEM, OTHER:STORAGE:TANK ASSEMBLY:PRESSURE RELIEF DEVICES

Make : TRANSPORTATION Model : T80206 Year : 1993
Build Dates : 1993-08-01 - 1994-07-01
NHTSA CAMPAIGN ID Number : 95E005003
Date Owner's Notified: 0000-00-00 Date Received by ODI: 1995-08-14 Date Added to Database: 1995-09-20
Manufacturers Involved: TRANSIT BUS INTERNATIONAL
Manufacturer's Responsible for the Recall:
Manufacturer Campaign Number:
Component: FUEL SYSTEM, OTHER:STORAGE:TANK ASSEMBLY:PRESSURE RELIEF DEVICES
Potential Number Of Units Affected : 94
Summary:
      UPON EXPOSURE TO IMPURITIES IN THE NATURAL GAS FUEL IN COLD WEATHER, AN INTERNAL O-RING ON THESE DEVICES CAN BLISTER DURING DECOMPRESSION AFTER "FAST-FILL" REFUELING RESULTING IN SEAL LEAKAGE.
Consequence:
      INTERNAL DAMAGE TO THE O-RING SEAL COULD CAUSE ARELEASE OF CNG. IF CNG WERE RELEASED TO THE ENVIRONMENT AND AN IGNITION SOURCE WERE PRESENT, A FIRE COULD OCCUR.
Remedy:
      MIRADA IS CONDUCTING THE OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. DEALERS WILL REPLACE RECALLED UNITS WITH NEW DEVICES THAT ARE NOT SUSCEPTIBLE TO O-RING DAMAGE FROM NON-METHANE COMPONENTS OF THE GAS SUPPLY WHEN THE DEVICES ARE DEVELOPED.
Report Initiator: ODI E Report
Regulation Part Number: Federal Motor Vehicle Safety Standard Number:
Notes:
      SYSTEM: FUEL; COMPRESSED NATURAL GAS 'CNG'; PRESSURE RELIEF VALVE/DEVICE.VEHICLE DESCRIPTION: TRANSIT BUSES EQUIPPED WITH CNG TANKS WHICH UTILIZE MIRADA B-51300 THERMALLY ACTUATED PRESSURE RELIEF DEVICES. NOTE: IF THE VALVES HAVE NOT BEEN REPLACED FREE OF CHARGE WITHIN A REASONABLE TIME, PLEASE CONTACT TBII AT 1-505-347-3000 OR MIRADA AT 1-612-448-3686.ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.