TEREX TZ-50 2004: ELECTRICAL SYSTEM
Make : TEREX | Model : TZ-50 | Year : 2004 |
Build Dates : 2004-02-12 - 2005-05-19 | ||
NHTSA CAMPAIGN ID Number : 06V484000 | ||
Date Owner's Notified: 2007-01-11 | Date Received by ODI: 2006-12-15 | Date Added to Database: 2006-12-27 |
Manufacturers Involved: Genie Industries, Inc. | ||
Manufacturer's Responsible for the Recall: | ||
Manufacturer Campaign Number: 060010 | ||
Component: ELECTRICAL SYSTEM | ||
Potential Number Of Units Affected : 347 | ||
Summary:
ON CERTAIN TRAILER MOUNTED AERIAL WORK PLATFORM BOOMS, THE OUTRIGGERS "STABILIZERS" CAN FUNCTION WHEN THE MACHINE IS NOT IN A FULLY STOWED POSITION. |
||
Consequence:
THE DOWN LIMIT SWITCH AND ITS LOCATION ON THE MACHINE ALLOW THE LIMIT SWITCH TO BE ACTIVATED WHEN IT COMES IN CONTACT WITH THE BOOM ARM, MAKING IT POSSIBLE TO RAISE THE OUTRIGGERS WHILE THE PLATFORM IS ELEVATED, INCREASING THE RISK OF INJURY TO THE OPERATOR. |
||
Remedy:
GENIE WILL PROVIDE A LIMIT SWITCH REPLACEMENT KIT AND INSTALLATION INSTRUCTIONS TO OWNERS OF ALL AFFECTED MACHINES. THE RECALL BEGAN ON JANUARY 11, 2007. OWNERS MAY CONTACT GENIE AT 1-877-738-7530. |
||
Report Initiator: MFR | V Report | |
Regulation Part Number: | Federal Motor Vehicle Safety Standard Number: | |
Notes:
GENIE RECALL NO. 060010.CUSTOMERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 'TTY 1-800-424-9153', OR GO TO HTTP://WWW.SAFERCAR.GOV. |