NEOPLAN AN440 1995: FUEL SYSTEM, OTHER:STORAGE:TANK ASSEMBLY

General Information

NHTSA Campaign ID Number: 96V183000

Make Model Year
NEOPLAN AN440 1995
Date Owners Notified Date Received by ODI Date Added to Database
1996-09-19 1996-09-23 1996-10-01

Production Dates: 1995-05-18 - 1997-11-06

Manufacturers Involved: NEOPLAN USA CORPORATION

Component: FUEL SYSTEM, OTHER:STORAGE:TANK ASSEMBLY

Potential Number Of Units Affected: 235

Report Initiator: ODI ODI Report

Summary

THE TYPE 4 COMPRESSED NATURAL GAS "CNG" FUEL TANK SUPPLIED BY EDO CANADA CAN RUPTURE DURING FUELING.

Consequence

RUPTURE OF A CNG FUEL TANK CAN CAUSE CNG LEAKAGE INCREASING THE RISK OF A FIRE OR EXPLOSION.

Remedy

EACH TANK IS BEING VISUALLY INSPECTED, ASSISTED BY DYE PENETRANT AND RESONANCE TESTED. A DETECTION SHIELD IS PLACED UNDER EACH PAIR OF TANKS, UNDER THE BUS, TO PROVIDE EASE OF INSPECTION FOR ANY DAMAGE. ANY DAMAGED TANK WILL BE REPLACED.

Notes

OWNER NOTIFICATION:OWNER NOTIFICATION HAS ALREADY BEGUN. NOTE:OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT NEOPLAN AT 1-719-336-3256.ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.