INTERNATIONAL RH 2019: SERVICE BRAKES, AIR

General Information

NHTSA Campaign ID Number: 18V597000

Make Model Year
INTERNATIONAL RH 2019
Date Owners Notified Date Received by ODI Date Added to Database
2018-10-23 2018-09-07 2018-09-12

Production Dates: 2018-06-22 - 2018-07-25

Manufacturers Involved: International Motors, LLC

Manufacturer Campaign Number: 18512

Component: SERVICE BRAKES, AIR

Potential Number Of Units Affected: 2089

Report Initiator: MFR MFR Report

Summary

Navistar, Inc. "Navistar" is recalling certain 2019 International HX, DuraStar, WorkStar, HV, LoneStar, LT, MV, and RH vehicles, and IC Bus HC, CE, and RE vehicles equipped with long stroke brake chambers and spring actuated parking brakes. The spring actuated parking brake may be improperly crimped to the long stroke service brake chamber, causing a service brake air leak and the possible separation of the spring brake chamber from the service brake section.

Consequence

An air leak or separation of the spring brake chamber can increase the needed stopping distance, increasing the risk of a crash.

Remedy

Navistar will notify owners, and dealers will replace the brake chamber assemblies from the suspected lot, free of charge. The recall began October 23, 2018. Owners may contact Navistar customer service at 1-800-448-7825. Navistar's number for this recall is 18512.

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 'TTY 1-800-424-9153', or go to www.safercar.gov.