HME 1871 2018: ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS
NHTSA Campaign ID Number: 20V104000
Make | Model | Year |
---|---|---|
HME | 1871 | 2018 |
Date Owners Notified | Date Received by ODI | Date Added to Database |
2020-05-18 | 2020-02-24 | 2020-02-24 |
Production Dates: 2017-12-01 - 2018-07-17
Manufacturers Involved: HME, Inc.
Component: ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS
Potential Number Of Units Affected: 174
Report Initiator: MFR MFR Report
HME, Inc. "HME" is recalling certain 2016-2020 AF1, 1871 and SFO emergency vehicles. The fuse box may be missing an O-Ring seal, potentially allowing moisture or contaminants into the fuse box.
If moisture or contaminants enter the fuse box, the fuse box may overheat or malfunction, increasing the risk of a crash.
HME will notify owners and will provide replacement fuse boxes, free of charge. The recall began May 18, 2020. Owners may contact HME customer service at 1-616-534-1463.
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 'TTY 1-800-424-9153', or go to www.safercar.gov.