GLAVAL BUS TITAN II 2015: ENGINE AND ENGINE COOLING:EXHAUST SYSTEM

General Information

NHTSA Campaign ID Number: 15V596000

Make Model Year
GLAVAL BUS TITAN II 2015
Date Owners Notified Date Received by ODI Date Added to Database
2015-10-07 2015-09-24 2015-09-24

Production Dates: 2011-10-05 - 2015-09-11

Manufacturers Involved: Forest River, Inc.

Manufacturer Campaign Number: 35-20222015-0091

Component: ENGINE AND ENGINE COOLING:EXHAUST SYSTEM

Potential Number Of Units Affected: 17

Report Initiator: MFR MFR Report

Summary

Forest River, Inc. "Forest River" is recalling certain model year 2011-2016 Glaval Titan II Low Floor diesel transit buses manufactured October 5, 2011, to September 11, 2015. During installation of the floor decking, a screw may have pierced the exhaust tube.

Consequence

If the exhaust tube was pierced and the screw is removed, exhaust fumes may enter the passenger area. Additionally, there is an increased risk of a fire.

Remedy

Forest River will notify owners, and dealers will remove and inspect the exhaust system, sealing or replacing it, as necessary, free of charge. The recall began on October 7, 2015. Owners may contact Forest River customer service at 1-800-445-2825 ext 167. Forest River's number for this recall is 35-20222015-0091.

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 'TTY 1-800-424-9153', or go to www.safercar.gov.