FORD F250 1992: FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
Make : FORD | Model : F250 | Year : 1992 |
Build Dates : 0000-00-00 - 0000-00-00 | ||
NHTSA CAMPAIGN ID Number : 93V125000 | ||
Date Owner's Notified: 1993-10-28 | Date Received by ODI: 1993-08-02 | Date Added to Database: 1993-07-27 |
Manufacturers Involved: Ford Motor Company | ||
Manufacturer's Responsible for the Recall: | ||
Manufacturer Campaign Number: | ||
Component: FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY | ||
Potential Number Of Units Affected : 1131000 | ||
Summary:
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE. |
||
Consequence:
SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION. |
||
Remedy:
REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES. |
||
Report Initiator: ODI | V Report | |
Regulation Part Number: | Federal Motor Vehicle Safety Standard Number: | |
Notes:
SYSTEM: FUEL; FUEL TANK ASSEMBLY.VEHICLE DESCRIPTION: LIGHT TRUCKS AND CHASSIS CABS WITH GASOLINE ENGINES ANDDUAL FUEL TANKS.NOTE: IF YOUR VEHICLE IS PRESENTED TO AN AUTHORIZED DEALER ON AN AGREED SERVICEDATE AND THE REMEDY IS NOT CORRECTED WITHIN A REASONABLE TIME WITHOUT CHARGEOR THE REMEDY DOES NOT CORRECT THE SAFETY-RELATED DEFECT OR NONCOMPLIANCE,PLEASE CONTACT FORD'S CUSTOMER ASSISTANCE CENTER, 300 RENAISSANCE CENTER,P.O. BOX 43360, DETROIT, MI 48243. ALSO CONTACT THE NATIONAL HIGHWAY TRAFFICSAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393. |