ELDORADO FALCON 1981: STRUCTURE:FRAME AND MEMBERS

General Information

NHTSA Campaign ID Number: 82V059000

Make Model Year
ELDORADO FALCON 1981
Date Owners Notified Date Received by ODI Date Added to Database
1982-06-04 1982-06-07 1982-07-06

Production Dates: 1980-03-01 - 1982-03-01

Manufacturers Involved: Eldorado National-Kansas

Component: STRUCTURE:FRAME AND MEMBERS

Potential Number Of Units Affected: 233

Report Initiator: ODI ODI Report

Summary

THE MOUNTING OF THE CROSSMEMBER MAY BE INSUFFICIENT. CROSSMEMBERS ARE MOUNTED TO A SHIM PIECE OF SQUARE TUBING AND THEN THIS ENTIRE STRUCTURE IS MOUNTED TO THE FRAME. THE SMALL SHIM PIECE COULD BECOME DETACHED FROM THE CROSSMEMBER WHICH WOULD ALLOW THE BODY TO MOVE DOWN TWO INCHES. THIS MOVEMENT COULD PUNCTURE THE FUEL TANK.

Remedy

THE CROSS MEMBER MOUNT REINFORCEMENTS WILL BE INSTALLED BY DEALER, IF NECESSARY.

Notes

VEHICLE DESCRIPTION: BUSES.SYSTEM: STRUCTURE; CROSSMEMBERS.CONSEQUENCES OF DEFECT: THE FUEL TANK COULD EXPLODE AND PERSONAL INJURY ANDPROPERTY DAMAGE COULD RESULT.