CM TRAILERS NOMAD 1995: ELECTRICAL SYSTEM:FUSES AND CIRCUIT BREAKERS
Make : CM TRAILERS | Model : NOMAD | Year : 1995 |
Build Dates : 1994-01-01 - 1995-04-01 | ||
NHTSA CAMPAIGN ID Number : 95E016002 | ||
Date Owner's Notified: 0000-00-00 | Date Received by ODI: 1995-07-31 | Date Added to Database: 1995-10-11 |
Manufacturers Involved: Skyline Corporation | ||
Manufacturer's Responsible for the Recall: | ||
Manufacturer Campaign Number: | ||
Component: ELECTRICAL SYSTEM:FUSES AND CIRCUIT BREAKERS | ||
Potential Number Of Units Affected : 12945 | ||
Summary:
A SOLDER BRIDGE ON THE PRINTED CIRCUIT BOARD WITHIN THE FUSE PANEL OF THE POWER CONVERTER PASSED UNDETECTED THROUGH A TEST FIXTURE AND BYPASSES THE FUSE PROTECTING THE CIRCUIT. |
||
Consequence:
THIS SOLDER BRIDGE, WHEN COUPLED WITH A DEAD SHORT ELSE WHERE IN THE SYSTEM, CAN RESULT IN CIRCUIT OVERLOAD, OVERHEATING, AND EVEN FIRE, WITHOUT WARNING. |
||
Remedy:
DETAILED TEST INSTRUCTIONS ARE BEING PROVIDED. IF A DEFECTIVE FUSE PANEL IS FOUND, A NEW REPLACEMENT PANEL WILL BE INSTALLED. |
||
Report Initiator: MFR | E Report | |
Regulation Part Number: | Federal Motor Vehicle Safety Standard Number: | |
Notes:
SYSTEM: ELECTRICAL; FUSE AND FUSE RECEPTICLE.VEHICLE DESCRIPTION: RECREATIONAL VEHICLES EQUIPPED WITH MAGNETEK POWER CONVERTERS WHICH USE DORAN MANUFACTURING FUSE PANELS. NOTE: IF THE FUSE PANELS ARE NOT REPLACED FREE OF CHARGE WITHIN A REASONABLE TIME, PLEASE CONTACT SKYLINE AT 1-219-294-6521. ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393. |