CHRYSLER E CLASS 1983: FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
NHTSA Campaign ID Number: 82V091000
Make | Model | Year |
---|---|---|
CHRYSLER | E CLASS | 1983 |
Date Owners Notified | Date Received by ODI | Date Added to Database |
1982-09-17 | 1982-09-22 | 1982-10-08 |
Production Dates: 1982-08-01 - 1982-09-01
Manufacturers Involved: Chrysler (FCA US, LLC)
Component: FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
Potential Number Of Units Affected: 5234
Report Initiator: MFR MFR Report
THE INVOLVED VEHICLES MAY BE EQUIPPED WITH AN ELECTRICAL FUEL FILLER DOOR RELEASE WHICH IS ACTIVATED THROUGH A COILED CURRENT CARRYING WIRE "A SOLENOID". A SHORT IN THE SOLENOID COULD CAUSE SPARKING AT THE ATTACHING SCREWS OF THE SOLENOID.
A SOLENOID GROUND WIRE WILL BE INSTALLED, BY THE DEALER, TO PREVENT SPARKING OF SOLENOID.
VEHICLE DESCRIPTION: PASSENGER VEHICLES.SYSTEM: FUEL; FUEL FILLER PIPE CAP.CONSEQUENCES OF DEFECT: ELECTRICAL SPARKING AT THE SOLENOID ATTACHING SCREWSCOULD IGNITE ANY FUEL VAPORS THAT MAY BE PRESENT AT THE FUEL FILLER PIPE CAP.PERSONAL INJURY AND FIRE DAMAGE COULD RESULT.