AMERICAN LAFRANCE EAGLE 2002: ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR

General Information

NHTSA Campaign ID Number: 03V089000

Make Model Year
AMERICAN LAFRANCE EAGLE 2002
Date Received by ODI Date Added to Database
2003-03-13 2003-03-20

Production Dates: 1997-01-02 - 2004-01-19

Manufacturers Involved: FREIGHTLINER LLC

Manufacturer Campaign Number: FL-406

Component: ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR

Potential Number Of Units Affected: 9

Report Initiator: MFR MFR Report

Summary

ON CERTAIN FIRE TRUCKS EQUIPPED WITH HARRISON HYDRA-GEN GENERATOR PUMPS, THE TUBING CONNECTING THE SOFT START TO THE GENERATOR PUMP CAN BREAK AWAY FROM THE FITTING AND SPRAY HYDRAULIC FLUID ONTO THE EXHAUST.

Consequence

THIS CAN CAUSE A FIRE THAT COULD ENDANGER PEOPLE IN THE VICINITY, THE VEHICLE ITSELF, AND NEARBY PROPERTY.

Remedy

HARRISON HYDRA-GEN NOTIFIED OWNERS ON JANUARY 15, 2003. DEALERS WILL REMOVE TWO PIECES OF STEEL TUBING AND REPLACE THEM WITH A HIGH PRESSURE HOSE. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITH A REASONABLE TIME SHOULD CONTACT HARRISON HYDRA-GEN AT 1-800-723-3334 OR AMERICAN LAFRANCE/FREIGHTLINER AT 1-800-385-4357.

Notes

FREIGHTLINER RECALL NO. FL-406.CUSTOMERS CAN ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-888-DASH-2-DOT '1-888-327-4236'.