ALTEC AH85 2002: EQUIPMENT

General Information

NHTSA Campaign ID Number: 12V456000

Make Model Year
ALTEC AH85 2002
Date Owners Notified Date Received by ODI Date Added to Database
2012-11-06 2012-09-18 2012-09-18

Manufacturers Involved: Altec Industries, Inc.

Manufacturer Campaign Number: CSN 570

Component: EQUIPMENT

Potential Number Of Units Affected: 245

Report Initiator: MFR MFR Report

Summary

Altec Industries, Inc. is recalling certain model year 2002-2009 AH75/85/100 and HL125 aerial device vehicles equipped with 16-foot radial outriggers. An improper torque was applied to the outrigger cylinder piston retention system during assembly. As a result, the cylinder could loosen from the rod allowing the outrigger leg to protrude beyond the confines of the chassis when it is in a stowed position.

Consequence

If the cylinder loosens from the rod, the outrigger could strike a person or object, increasing the risk of injury or property damage.

Remedy

Altec will notify owners, and will increase the torque on the piston free of charge. The safety recall began on November 6, 2012. Owners may contact Altec Industries at 1-877-462-5832.

Notes

Altec's recall campaign number is CSN 570.Customers may contact the National Highway Traffic Safety Administration's Vehicle Safety Hotline at 1-888-327-4236 'TTY: 1-800-424-9153'; or go to http://www.safercar.gov.