ALTEC AH100 2006: ELECTRICAL SYSTEM

General Information

NHTSA Campaign ID Number: 13V378000

Make Model Year
ALTEC AH100 2006
Date Received by ODI Date Added to Database
2013-08-21 2013-08-27

Production Dates: 2005-04-01 - 2013-04-28

Manufacturers Involved: Altec Industries, Inc.

Manufacturer Campaign Number: CSN 585

Component: ELECTRICAL SYSTEM

Potential Number Of Units Affected: 263

Report Initiator: MFR MFR Report

Summary

Altec is recalling certain model year 2005-2013 AH75/85/100 aerial devices manufactured April 2005 through April 2013; and equipped with current leakage monitoring systems. The cable for the current leakage monitoring system may be too long and may breach the gap provided by the lower boom fiberglass insert chassis insulating system.

Consequence

If the gap is breached, then the boom may conduct electrical current, increasing the risk of electrical shock to the operator.

Remedy

Altec will notify owners and dealers will inspect and properly secure the leakage monitor cable. The recall is expected to begin during September 2013. Altec's recall number is CSN 585. Owners may contact Altec at 1-877-462-5832.

Notes

Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 'TTY 1-800-424-9153', or go to www.safercar.gov.